Why is daisychaining multiple extension cords considered unsafe, even if only done to the length of a standard cable?

"never plug extension cords into extension cords" is probably the most common piece of electrical related advice I've ever heard. But if you have, say, 2 x 2m long extension cords, and you plug one into the other, why is that considered a lot more unsafe than just using a single 4 or 5 meter cord?

Does it just boil down to that extra connection creating another opportunity for the prongs to slip out and cause a spark or short circuit? Or is there something else happening there?

For that matter - why aren't super long extension cords (50 or more meters) considered unsafe? Does that also just come down to a matter of only having 2 connections versus 4 or more on a daisy chained cord?

Followup stupid question: is whatever causes piggybacked extension cords to be considered unsafe actually that dangerous, or is it the sort of thing that gets parroted around and misconstrued/blown out of proportion? On a scale from "smoking 20 packs of cigarettes a day" to "stubbing your toe on a really heavy piece of furniture", how dangerous would you subjectively rate daisy chaining extension cords, assuming it was only 1 hop (2 extension cords, no more), and was kept under 5 or 10 metres?

I'm sure there's probably somebody bashing their head against a wall at these questions, but I'm not trying to be ignorant, I'm just curious. Thank you for tolerating my stupid questions

141

You're viewing a single thread.

141 comments
  • On a scale from "smoking 20 packs of cigarettes a day" to "stubbing your toe on a really heavy piece of furniture", how dangerous would you subjectively rate daisy chaining extension cords

    As dangerous as one extension cord of their combined length. Don't forget to verify that every cord rating is above load rating. I recommend to use at least same rating as circuit breaker or get extension cord with circuit breaker built in and never decrease rating down the line without circuit breaker before it, so even if you somehow overload it, there will be protection from it.

    AND NEVER COIL OR THERMALY INSULATE! Cords rely on convection for heat dissipation, and spooling and insulating reduces it, thus increasing electrical insulator temperature until it melts and spontaneously combusts. This applies to extension cords in general.